Benefits of a ballasted roof system.
Roof ballast depth.
In the field of the roof a minimum of 10 lbs s f.
The stones used in ballasted roofing are generally 1 5 2 5 inches in diameter and applied in a thicker layer.
Installs very quickly since no fasteners or adhesives are used.
Ballast is required with 20 lbs s f.
The weight of the ballast equals the weight of the water it causes the vessel to displace.
Ballast stones are usually one to two inches thick and applied more generously than on a built up roof.
Ballasted roof systems are simultaneously a roofer s best friend and arch nemesis.
Stone ballast typically requires crushed graded stone placed over a stone filter sheet rolled out over the insulation.
Though not as common as they used to be ballasted roof systems still prove to be a viable solution for today s commercial roof needs.
Seawater weighs 64 1 pounds per cubic foot.
Doesn t produce any foul smell during construction.
Modular trays can have a variety of different outlet designs according to the goals of the installation e g reduce peak flows achieve specific lag time for target events etc.
Finally the ballast stone or and pavers are laid down throughout the roof system.
The depth of the ballast or media contained in the trays can be varied depending on the desire to reduce the presence of open water surfaces.
For built up roofing the gravel was generally 25 5 inches in diameter.
Divide the amount of ballast to be added or removed by 64 1.
Simply put a ballasted roof is easy to install and basically guaranteed maintenance work for a roofer.
Or you may call us at 440 946 2233.
Holes mean roof leaks and roof leaks mean call the roofer.
An insufficient depth of ballast causes overloading of the underlying soil and in unfavourable conditions overloading the soil causes the track to sink usually unevenly.
The gravel used in built up roofing what the roofing contractors were used to was not the same as that used in a ballasted roof.
1 a leak is very difficult to locate because the water runs freely in numerous directions and for longer distances under the loose laid membrane.
Needed at perimeters and at large penetrations.
Contact hydrotech for specific installation guidelines.
If you remove 64 1 pounds of ballast then the vessel will displace 1 cubic foot of water less than it did before the 64 1 pounds of ballast was removed.
Most roofers typically installed 10 15 pounds of ballast per square foot.
Roofing southwest a ballast system helps cut roof system application costs as it takes less time to install since sealing the layers together isn t necessary.
Track ballast should never be laid down less than 150 mm 6 inches thick and high speed railway lines may require ballast up to 0 5 metres 20 inches thick.
To learn more about selecting a commercial roofer in cleveland ohio simply fill out the form on this page and a member of our team will be in touch.
The heavier stones provide substantial protection against wind gusts.
Ballasted flat roofs are a popular choice especially for commercial buildings.
Additional benefits of ballast on a flat roof.